Charging Pile Instructions-V2.0
42
51
Output short circuit
Check
if
the
output
is
short-circuited
60/61
Slave-machine 1/2communication
timeout
Check the communication line
between the slave-machine 1/2
and main control board
75
Highest single voltage is greater
than the protection value
Check the BMS communication
message
Power Module Fault classification number: 31 (Module 0) ~ 94 (Module 64)
Fault Code
Fault Name
Treatment
37
CAN communication abnormal
Check the communication line
between the charging module and
the control board
BMS Fault classification number: 21 (Connector 1) ~ 28 (Connector 8)
Fault codes 50-86 these faults are reported as fault codes by the vehicle end. In case of such
faults, the charging message should be intercepted and submitted to the R&D for analysis.
Fault codes 101 ~ 112 refer to the fault codes reported by the European standard SECC
(PLC). In case of failure, the SECC (PLC) shall be checked for interference or hardware
damage, and shall be replaced after comparison test and verification.