Charging Pile Instructions-V2.0
7
16
Temperature alarm of air outlet
100
℃
Adjustable
17
Emergency shutdown protection
yes
-
Press emergency button, in
case of emergencies.
18
Input inrush current
≤
110%
A
Input current
19
Soft-starting time
3~8
S
20
Start output pulse
voltage
≤
5%
V
Output DC current ≥ 30A
Output DC current
<
30A
current
≤
5%
≤
1.5
A
21
Output current measured error
≤±(
1.5%Im+1
)
A
Im: actual output current of
charger
22
Output voltage measured error
≤±
5
V
23
Measured value update time
≤
1
S
24
Output insulation protection
yes
-
In case of 100Ω/V
<
R
<
500Ω/V, the charger sounds an
alarm of abnormal insulation
but still normally charges; in
case of
<
100Ω/V, the charger
stops charging.
25
Contactor adhesion alarm
yes
-
26
Battery voltage detection function
yes
-
27
Battery voltage reverse function
yes
-
28
Countercurrent protection function
yes
-
29
Door protection function
yes
-
5.4 EMC characteristics
No.
Item
Technical requirements
Remark
1
Conducted disturbance for AC power input port
Pass
2
Asymmetric mode conducted emissions at wired network
port
Pass
3
Conducted disturbance for DC CPT port
Pass
4
Voltage transient disturbance for DC CPT port
Pass
5
Radiated disturbance (2 KHZ TO 185 KHZ)
Pass
6
Radiated disturbance (30MHZ-1000MHZ)
Pass
7
Radiated disturbance (1000MHZ-6000MHZ)
Pass
8
Radio-frequency electromagnetic field amplitude
Pass