Charging Pile Instructions-V2.0
9
9
Ac input
lightning
protection
Maximum continuous operating
voltage is 385VAC
;
Nominal discharge current is 20kA
;
Maximum discharge current is 40kA
Voltage protection level is under
1.8kV
-
5.6 Other characteristics
No.
Item
Technical
requirements
Unit
Remark
1
DC output charging interface
Comply with
IEC62196-3-2014
-
2
Standby power consumption
≤
20+5*N
W
N: charging interface quantity
3
Noise
≤65
dB
4
Current display accuracy
≤±1
%
5
Voltage display accuracy
≤±0.5
%
6
IP protection class
IP55
-
7
Cables of the charging gun
10
M
Optional
8
The protection of three
proofing
moisture proofing, salt
spray proofing and
fungus proofing
-
There are several printed circuit
boards in the system. The
connector and other circuits carry
out moisture proofing, salt spray
proofing and fungus proofing
treatment to ensure that the
charger can run normally in the
environment of damp and salt
fog.
9
Antirust protection
Anti oxidation
-
The double layer antirust
measures are taken for the iron
shell of the system and the iron
support and parts exposed
outside. The non iron metal shell
has anti oxidation protection film
or anti oxidation treatment.
10
Environmental protection
Meet requirements of
2011/65/EU
;
no
cadmium, hydride and
fluoride
-