Installation
30
FES/UES 07 25 13 Bl.30
Connection
For installation, the connection space must be made accessible.
-
In order to remove the front panel
, you must unscrew the screws
. The front panel can then be removed by pulling it downwards.
Electrics
The terminal box
is accessible from the front. It is located on the
right behind the middle front panel
.
Connect the appliance as shown in the applicable wiring diagram.
[
The connection cable leading through the appliance must be fully
sheathed from the connection point up to the entrance to the
terminal box!
The number of the applicable wiring diagram is on the appliance
identification plate (see page 2).
The wiring diagrams for the basic version are part of these instructions.
Wiring diagrams for special versions are provided in the connection
space of the appliance.
Compare the numbers of the wiring diagrams with the appliance
identification plate. For special versions keep the wiring diagrams with
these instructions and identify the wiring diagrams which do not apply
accordingly!
☞
Activate the protection-against-boiling-dry function by pressing
the button on the left side of the electrical connector box.
[
After completing all installation work, remount all covers and
panels and screw them tight. Only then should the customer’s all-
pole cut-off device (e.g. fuses) be closed.