5-6
IM XL100C-E
Measured/Calculated Data
• The FD command is used to output the data.
• The measured/computed data that are output using the FD command contains only
the mantissa when binary data output is specified. By combining with the binary
display data or the decimal place obtained with the FE command, the correct
measured/calculated data can be derived.
• Syntax
The measured/calculated data are output in the following syntax along with the date
and time information for each channel.
EA
<CRLF>
DATE_yy/mo/dd
<CRLF>
TIME_hh:mi:ss.mmmt
<CRLF>
s_kcca1a2a3a4uuuuuufdddddE-pp
<CRLF>
............
EN
<CRLF>
yy
year (00 to 99)
;mo
month (01 to 12)
;dd
day (01 to 31)
;hh
hour (00 to 23)
;mi
minute (00 to 59)
;ss
second (00 to 59)
;mmm
millisecond (000 to 999. A period is
placed between seconds and milli-seconds)
;t
reserved (space)
s
Data status (N, S, O, E)
N
: Normal/
S
: Skip/
O
: Over/
E
: Error
k
Channel type
0
: Measurement analog channel/P: Pulse channel/D: Logic input channel/A:
Calculation channel/
C
: Communication channel
cc
Channel number
01
to
32
a1a2a3a4
a1
Alarm status
a2
Reserved (space character at all times)
a3
Reserved (space character at all times)
a4
Reserved (space character at all times)
(H, L, I, O, or space)
(
H
(High limit alarm)/
L
(Lower limit alarm)/
I
(Window IN alarm)/
O
(Window OUT
alarm))
Reserved (
h
,
l
,
T
,
t
,
R
, and
r
)
Space (no alarm)
uuuuuu
Unit information (6 characters, left-justified)
mV____:mV/V_____:V/^C____:
°
C/Mc____:Mc/kc___:kc/rpm__:rpm/xxxxxx: (User-
defined character string)
f
Sign (+, -)
ddddd
Mantissa (
00000
to
99999
, 5 digits)
• Eight digits for calculated data.
• For abnormal data (data status is E) or data of which the mantissa or the exponent
exceeds the range (data status is O), the mantissa is set to 99999 (99999999 for
calculated data).
pp
Exponent (
00
to
04
)
_
Space
5.2 Response Syntax