Administrator’s Guide for SIP-T2 /T3 /T4 /T5 /CP920 IP Phones
502
Supported: timer
Content-Length: 0
Topic
Session Timer Configuration
The following table lists the parameters you can use to configure the session timer.
Parameter
account.X.session_timer.enable
[1]
<MAC>.cfg
Description
It enables or disables the session timer.
Permitted
Values
0
-Disabled
1
-Enabled, the phone will send periodic UPDATE requests to refresh the session during a call.
Default
0
Web UI
Account > Advanced > Session Timer
Parameter
account.X.session_timer.expires
[1]
<MAC>.cfg
Description
It configures the interval (in seconds) for refreshing the SIP session during a call.
An UPDATE will be sent after 50% of its value has elapsed. For example, if it is set to 1800 (1800s),
the phone will refresh the session during a call every 900 seconds.
Note
: It works only if “account.X.session_timer.enable” is set to 1 (Enabled).
Permitted
Values
Integer from 90 to 7200
Default
1800
Web UI
Account > Advanced > Session Expires (90~7200s)
Parameter
account.X.session_timer.refresher
[1]
<MAC>.cfg
Description
It configures who refreshes the SIP session during a call.
Note
: It works only if “account.X.session_timer.enable” is set to 1 (Enabled).
Permitted
Values
0
-UAC
1
-UAS
Default
0
Web UI
Account > Advanced > Session Refresher
[1]
X is the account ID. For T57W/T54W/T48U/T48S/T48G/T46U/T46S/T46G/T29G, X=1-16; for
T53W/T53/T43U/T42G/T42U/T42S, X=1-12; for T41P/T41S/T27G, X=1-6; for T33P/T33G, X=1-4; for
T40P/T40G/T23P/T23G, X=1-3; for T31P/T31G/T31/T21(P) E2, X=1-2; for T30P/T30/T19(P) E2/CP920, X=1.
Reboot in Talking
Reboot in talking feature allows the phones to reboot during an active call when it receives a reboot Notify mes-
sage.
Topic