6.2 List of Servo Parameters
6-22
Pn511
2
Input Signal Selections
5
0000h to
FFFFh
–
6543h
Rotary
After
restart
Setup
*1
Pn512
2
Output Signal Inverse
Settings
0000h to
1111h
–
0000h
Rotary
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/DEC (Origin Return Deceleration Switch Input) Signal Allocation
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
n.
X
/EXT1 (External Latch Input 1) Signal Allocation
0 to 3
The signal is always inactive.
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
7 to C
The signal is always inactive.
n.
X
/EXT2 (External Latch Input 2) Signal Allocation
0 to F
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
cations.
n.X
/EXT3 (External Latch Input 3) Signal Allocation
0 to F
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
cations.
n.
X
Output Signal Inversion for CN1-1 and CN1-2 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-23 and CN1-24 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-25 and CN1-26 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.X
Reserved parameter (Do not change.)