www.dadehpardazan.ir 88594014-15
3.2 System Configuration Diagram
3-7
3
Wiring and Connection
(3)
SGDV-
D05A
Use a 24 VDC power supply with double insulation or reinforced insulation. (The power
supply is not included)
Before connecting an external regenerative resistor to the SERVOPACK, refer to
necting Regenerative Resistors
R S T
24 VDC
power supply
∗
1
SGDV-
D05A
SERVOPACK
Power supply
Three-phase 400 VAC
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power supply
line by shutting the
circuit OFF when
overcurrent is
detected.
Used to eliminate
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory) inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function devices
I/O signal cable
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
Host controller
Regenerative
resistor
*
2
Linear servomotor
main circuit cable
Serial converter unit
Cable for connecting a
serial converter unit
Linear servomotor
with core
Linear scale
(Not included)
Cable for connecting a
hall sensor
Cable for connecting a