www.dadehpardazan.ir 88594014-15
3 Wiring and Connection
3.2.3 Connecting to SGDV-
25
SERVOPACK (M-
III
Model)
3-14
Using a Single-phase, 200-V Power Supply
The
-V Series SERVOPACK for a 200-V power supply input has input specifica-
tions for a three-phase power supply, but some models can also be used with a single-
phase 200-V power supply. For details, refer to
-V Series User's Manual Design and
Maintenance Linear Motor/MECHATROLINK-III Communications Reference
(SIEP
S800000 65).
Before connecting an external regenerative resistor to the SERVOPACK, refer to
necting Regenerative Resistors
R
T
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic contactor
I/O signal cable
SGDV-
A25
SERVOPACK
Power supply
Single-phase 200 VAC
Protcts the power supply
line by shutting the
circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Turns the servo
ON and OFF.
Install a surge
absorber.
Personal
computer
Connection cable
for personal computer
Digital
operator
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
Connection cable
for digital operator
Host controller
Regenerative
resistor
*
Connect to the
MECHATROLINK-
III
Linear servomotor
main circuit cable
Serial converter unit
Cable for connecting a
serial converter unit
Linear servomotor
with core
Linear scale
(Not included)
Cable for connecting a
hall sensor
Cable for connecting a
linear scale