www.dadehpardazan.ir 88594014-15
3.2 System Configuration Diagram
3-9
3
Wiring and Connection
(2)
SGDV-
A15
Using a Three-phase, 200-V Power Supply
Before connecting an external regenerative resistor to the SERVOPACK, refer to
necting Regenerative Resistors
R S T
Connect to the
MECHATROLINK-
II
SGDV-
A15
SERVOPACK
Power supply
Three-phase 200 VAC
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor
*
When not using the safety function,
use the SERVOPACK with the safety
function jumper connector
(JZSP-CVH05-E, provided as
an accessory) inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
I/O signal cable
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
Host controller
Linear servomotor
main circuit cable
Serial converter unit
Cable for connecting a
serial converter unit
Linear servomotor
with core
Linear scale
(Not included)
Cable for connecting a
hall sensor
Cable for connecting a
linear scale