www.dadehpardazan.ir 88594014-15
3.3 Main Circuit Wiring
3-27
3
Wiring and Connection
3.3.3
When Using the SERVOPACK with a Single-phase 200 V
Power Input
Some models of
-V series three-phase 200 V power input SERVOPACK can be
used also with a single-phase 200 V power supply.
The following models support single-phase 200 V power input.
SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5A
When using the SERVOPACK with single-phase, 200 V power input, set parameter
Pn00B.2 to 1.
(1)
Parameter Setting
Single-phase Power Input Selection
Parameter
Meaning
When
Enabled
Classifica
tion
Pn00B
n.
0
[factory
setting]
Enables use of three-phase power sup-
ply for three-phase SERVOPACK.
After restart
Setup
n.
1
Enables use of single-phase power
supply for three-phase SERVOPACK.
WARNING
• If a single-phase 200 V is input to a single-phase 200 V power input supported
SERVOPACK without having changed the setting of Pn00B.2 to 1 (single-phase
power input), the main circuit cable open phase alarm (A.F10) will be detected.
• If a single-phase 200 V is input to the SERVOPACK models that do not support
single-phase power input, the main circuit cable open phase alarm (A.F10) will be
detected.
• When using a single-phase 200 V power supply, the SERVOPACK may not be
able to produce the same linear servomotor force-speed characteristics as using
a three-phase 200 V power input. Refer to the diagram of each motor force-speed
characteristics in
-V Series Product Catalog
(KAEPS80000042).