www.dadehpardazan.ir 88594014-15
5.4 Execution of Origin Setting (Fn020)
5-13
5
T
rial Operation (Checking Linear Servomotor Operation)
With SGDV SERVOPACK that support MECHATROLINK-II or MECHATROLINK-III,
“A.941” will not be shown, and “BB” will be displayed instead.
Using the Panel Operator
4
Press the
Key to start the ori-
gin setting. During origin setting,
“Scale Origin Set” will be displayed
blinking.
When the origin setting is
completed, the display stops
blinking, and the status will be
changed as BB
DONE
A.941
.
5
To enable the setting, turn OFF the
power to the SERVOPACK and then
ON again.
(cont’d)
Step
Display after operation
Keys
Operation
B B
S c a l O r i g i n S e t
Step
Display after operation
Keys
Operation
1
Press the MODE/SET Key to select the Util-
ity Function mode.
2
Press the UP or DOWN Key to select Fn020.
3
Press the DATA/SHIFT Key for approxi-
mately one second. The display shown on
the left will appear.
4
Keep pressing the UP Key until 0SET5
appears.
Note:
If the correct key is not properly pressed,
No_oP will be displayed blinking and the
display will return to that of step 1.
5
(Displayed blinking)
Press the MODE/SET Key to set the scale
origin.
When the origin is set, donE is displayed
blinking for approximately one second.
6
One second after
The display donE is changed to OSET5.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/