www.dadehpardazan.ir 88594014-15
3.2 System Configuration Diagram
3-19
3
Wiring and Connection
(3)
SGDV-
DE5A
Use a 24-VDC power supply with double insulation or reinforced insulation. (The power
supply is not included)
Before connecting an external regenerative resistor to the SERVOPACK, refer to
necting Regenerative Resistors
For connection to the command option module, refer to the user’s manual of the corre-
sponding option module.
R S T
*1
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
I/O signal cable
Power supply
Three-phase 400 VAC
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is
detected.
Used to eliminate
external noise from
the power line.
Turns the servo
ON and OFF.
Install a surge
absorber.
Connection cable
for digital operator
Connection cable
for personal computer
Personal
computer
When not using the safety function,
use the SERVOPACK with the safety
function jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
SGDV-
DE5A
SERVOPACK
Digital
operator
Regenerative
resistor
*
2
24VDC
power supply
*
1
Option module
*
3
External LED indicator,
external device, etc.
Linear servomotor
main circuit cable
Serial converter unit
Cable for connecting a
serial converter unit
Linear servomotor
with core
Linear scale
(Not included)
Cable for connecting a
hall sensor
Cable for connecting a
linear scale