www.dadehpardazan.ir 88594014-15
2.5 EMC Installation Conditions
2-59
2
Installation
Three-phase 400 V, SGDV-
D25A (
= 1R9, 3R5, 5R4,
8R4, 120, 170)
Products that have received CE marking are recommended for the 24 VDC power supply.
Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)
For more information on this filter, refer to
-V Series Product Catalog
. (KAEP S800000
42)
Symbol
Cable Name
Specification
I/O signal cable
Shield cable
Cable for safety unit
Shield cable
Linear servomotor main circuit cable
Shield cable
Linear scale connection cables
Shield cable
Control power cable
Shield cable
Main circuit cable
Shield cable
MECHATROLINK-III communication cable Shield cable
1
2
3
6
5
4
7
U, V, W
L1, L2, L3
24 V,
0 V
CN2
CN1
PE
PE
CN8
CN6A, CN6B
MECHATROLINK-
III
controller
SERVOPACK
Safety unit
Linear
scale
Linear
servomotor
Power supply:
Single-phase
200 VAC
Power supply:
Three-phase
400 VAC
Shield box
Clamp
Clamp
Core
Core
Clamp
Core
Core
Clamp
Noise
filter*
3
Core
Core
Surge
absorber
Surge
absorber
Core
Noise
filter*
2
Control
power
supply
24 VDC*
1
Clamp
Clamp
Clamp
One turn
One turn
Two turn
Two turn
One turn
Host controller