9 Appendix
9.1.2 Parameters
9-10
Pn143
Model Following Control Bias
(Forward Direction)
0 to 10000
0.1%
1000
Immediately
Tuning
−
Pn144
Model Following Control Bias
(Reverse Direction)
0 to 10000
0.1%
1000
Immediately
Tuning
−
Pn145
Vibration Suppression 1 Frequency A
10 to 2500
0.1 Hz
500
Immediately
Tuning
−
Pn146
Vibration Suppression 1 Frequency B
10 to 2500
0.1 Hz
700
Immediately
Tuning
−
Pn147
Model Following Control Speed
Feedforward Compensation
0 to 10000
0.1%
1000
Immediately
Tuning
−
Pn148
2nd Model Following Control Gain
10 to 20000
0.1/s
500
Immediately
Tuning
−
Pn149
2nd Model Following Control Gain
Compensation
500 to 2000
0.1%
1000
Immediately
Tuning
−
Pn14A
Vibration Suppression 2 Frequency
10 to 2000
0.1 Hz
800
Immediately
Tuning
−
Pn14B
Vibration Suppression 2 Compensa-
tion
10 to 1000
1%
100
Immediately
Tuning
−
Pn14F
Reserved (Do not change.)
-
-
0011
-
-
–
Pn160
Anti-Resonance Control Related
Switch
0000 to 0011
−
0010
Immediately
Tuning
−
Pn161
Anti-Resonance Frequency
10 to 20000
0.1 Hz
1000
Immediately
Tuning
−
Pn162
Anti-Resonance Gain Compensation
1 to 1000
1%
100
Immediately
Tuning
−
Pn163
Anti-Resonance Damping Gain
0 to 300
1%
0
Immediately
Tuning
−
Pn164
Anti-Resonance Filter Time Constant
1 Compensation
-1000 to 1000
0.01 ms
0
Immediately
Tuning
−
Pn165
Anti-Resonance Filter Time Constant
2 Compensation
-1000 to 1000
0.01 ms
0
Immediately
Tuning
−
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Reference
Section
0
1
Does not use anti-resonance control.
Uses anti-resonance control.
Anti-Resonance Control Selection
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change.)
Reserved (Do not change.)
0
1
Does not use adjust anti-resonance control automatically using the utility function.
Adjusts anti-resonance control automatically using the utility function.
Anti-Resonance Control Adjustment Selection
(Refer to 5.3.1, 5.4.1, 5.5.1, 5.7.1)
(Refer to 5.3.1, 5.4.1, 5.5.1, 5.7.1)