1.3 SERVOPACK Ratings and Specifications
1-3
1
Outline
1.3
SERVOPACK Ratings and Specifications
This section describes the ratings and specifications of SERVOPACKs.
1.3.1
Ratings
Ratings of SERVOPACKs are as shown below.
(1) SGDV Single-phase 100-V Ratings
∗
Refer to
3.7 Regenerative Resistors Connections
for details.
(2) SGDV Single-phase 200-V Ratings
∗1.
The official model number is SGDV-120AE5A008000.
∗2.
Refer to
3.7 Regenerative Resistors Connections
for details.
(3) SGDV Three-phase 200-V Ratings
∗
Refer to
3.7 Regenerative Resistors Connections
for details.
SGDV
(Single-phase, 100 V)
R70
R90
2R1
2R8
Continuous Output Current
[Arms]
0.66
0.91
2.1
2.8
Max. Output Current [Arms]
2.1
2.9
6.5
9.3
Regenerative Resistor
*
None/External
Main Circuit Power Supply
Single-phase, 100 to 115 VAC
, 50/60 Hz
Control Power
Single-phase, 100 to 115 VAC
, 50/60 Hz
Overvoltage Category
III
+
10%
−
15%
+
10%
−
15%
SGDV (Single-phase, 200 V)
120
*1
Continuous Output Current
[Arms]
11.6
Max. Output Current [Arms]
28
Regenerative Resistor
*2
Built-in/External
Main Circuit Power Supply
Single-phase, 220 to 230 VAC
, 50/60 Hz
Control Power
Single-phase, 220 to 230 VAC
, 50/60 Hz
Overvoltage Category
III
+
10%
−
15%
+
10%
−
15%
SGDV (Three-phase, 200 V)
R70
R90
1R6
2R8
3R8
5R5
7R6
120
180
200
330
550
Continuous Output Current
[Arms]
0.66
0.91
1.6
2.8
3.8
5.5
7.6
11.6
18.5
19.6
32.9
54.7
Max. Output Current [Arms]
2.1
2.9
5.8
9.3
11.0
16.9
17
28
42
56
84
130
Regenerative Resistor
*
None/External
Built-in/External
Exter
nal
Main Circuit Power Supply
Three-phase, 200 to 230 VAC
, 50/60 Hz
Control Power
Single-phase, 200 to 230 VAC
, 50/60 Hz
Overvoltage Category
III
+
10%
−
15%
+
10%
−
15%