6.12 Write Prohibited Setting (Fn010)
6-23
6
Utility Functions (Fn
)
(2) Operating Procedure
Follow the steps below to set
“
write prohibited
”
or
“
write permitted.
”
Setting values are as follows:
•
“P.
0000
”
: Write permitted (Releases write prohibited mode.) [Factory setting]
•
“P.
0001
”
: Write prohibited (Parameters become write prohibited from the next power ON.)
Step
Display Example
Keys
Operation
1
Press the
Key to view the main menu for the util-
ity function mode.
Use the
or
Key to move through the list,
select Fn010.
2
Press the
Key. The display switches to the exe-
cution display of Fn010.
3
Press the
Key to select one of the following set-
tings.
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
4
Press the
Key to save the setting value in the
SERVOPACK. When the saving is completed,
“DONE” is displayed in the status display.
5
Press the
Key to return to the Utility Function
Mode main menu.
6
Turn OFF the SERVOPACK power supply and then turn it ON again to validate the new setting.