37
10 Built-in Functions
10.1 Terminals for Automatic Machine
The following outlines the functions and usages of the terminals on the printed board Pr
(IF).
Line No.
171
173 146
147
153
154
(+)
(-)
197 198
Terminal
Name
Start signal
Current detection signal
Pulse synchronization signal
Emergency stop signal
Details
Starts when circuit is
closed.
Connect a dry contact of
24 VDC - 0.1 A or more
with less chattering.
Circuit is closed when current
flows.
Always open contact
Contact capacity is as follows:
・
24 VDC - 0.2 A or less
・
24 VDC - 0.2 A or less
Circuit is closed only during pulse
period.
Effective only in pulse mode.
Photocoupler capacity is as follows:
30 VDC - 20 mA or less.
Pay attention to the polarity.
A operation stop signal
Always closed contact
Connect a dry contact of
24 VDC - 0.1 A or more
with less chattering.
Settings can be made in the following modes:
Start signal
Current detection signal
Pulse synchronization signal
(Only when pulses provided)
Emergency stop signal
Output current
Pre-flow time
Example when Pulses Provided
Note: Prevent the noise from entering the wiring to the terminal stand.
Summary of Contents for MOTOWELD-T300D
Page 14: ...14 Fix the gas regulator to prevent it from falling Gas regulator Gas regulator stand...
Page 56: ...56 14 Connection Diagrams 14 1 Connection System Diagram...
Page 59: ...59 15 Lists of Service Components...
Page 60: ...60 Fig 15 1 YWE T30D Front Face Fig 15 2 YWE T30D Rear Face...
Page 63: ...63 Fig 15 3 YWE T30A D 0 Right Side Face Fig 15 3 YWE T30D Right Side Fade...
Page 65: ...65 Fig 15 4 YWE T30D Left Side Face...
Page 67: ...67 Fig 15 5 YWE T30D Base Section...
Page 69: ...69 Fig 15 6 YWE T30D Compartment Barrier Section...