50
13.2 Electrode and Gas Flow Rate for Various Welding Current
Table 13.2 Welding Current and Gas Flow Rate for Electrode Diameter
Welding Current (A)
Electrode
Diameter
(
φ
mm)
AC* DC
Electrode
Negative
DC
Electrode
Positive
Argon
Gas
Flow
Rate
(Litter/
min)
0.5
5 to 15
4 to 15
-
3 to 7
1.0
10 to 55
10 to 65
-
4 to 8
1.6
45 to 96
55 to 120
8 to 15
6 to 9
2.0
70 to 120
85 to 150
8 to 20
6 to 10
2.4
90 to 150
120 to 200
10 to 25
7 to 10
3.2
140 to 210 200 to 320
20 to 30
10 to 15
4.0
180 to 280 320 to 400
30 to 45
12 to 20
4.8
230 to 330 400 to 640
45 to 65
15 to 25
6.4
300 to 450 640 to 880
65 to 100
20 to 30
∗
These values are applied when the cleaning control knob is set to
Standard. Reduce the current value when it is set to Strong.
Note: In the welding current range of AC and DC electrode negative, the
lower limit indicates the minimum operational current for the pure
tungsten electrode, and the upper limit indicates the maximum
operational current for the thoriated tungsten current.
Summary of Contents for MOTOWELD-T300D
Page 14: ...14 Fix the gas regulator to prevent it from falling Gas regulator Gas regulator stand...
Page 56: ...56 14 Connection Diagrams 14 1 Connection System Diagram...
Page 59: ...59 15 Lists of Service Components...
Page 60: ...60 Fig 15 1 YWE T30D Front Face Fig 15 2 YWE T30D Rear Face...
Page 63: ...63 Fig 15 3 YWE T30A D 0 Right Side Face Fig 15 3 YWE T30D Right Side Fade...
Page 65: ...65 Fig 15 4 YWE T30D Left Side Face...
Page 67: ...67 Fig 15 5 YWE T30D Base Section...
Page 69: ...69 Fig 15 6 YWE T30D Compartment Barrier Section...