47
F
ig. 12.2 How to Check Gas System
Cause of Problem
Gas hose connection
failure
Faulty operation of gas
regulator valve and flow
rate adjusting knob
Magnetic valve is clogged
.
Magnetic valve failure
Refer to F
ig. 12.1.
W
ater pressure is not
sufficient.
Pressure switch failure
Water pressure
detecting circuit failure
Torch selector switch
failure
Gas circuit failure Pr
(MB2 and IF
)
Gas adjusting switch
failure
Is torch selector switch set to water cooing?
(Does fault monitor
flash?)
Check whether
wate
r- or air-cooled
torch is selected.
(Does fault monitor
flash?)
Does starting
relay 1Y operate?
Is voltage applied to magnetic valves (Nos. 113 to 138)?
Is there a "click" when magnetic valve moves?
Check Items
Set the gas
adjusting switch to adjustment.
Gas does not flow even when
the welding start signal is
turned ON.
Status
No gas flow when gas adjustment selector switch is set to “gas adjustment.”
Gas does not sto
p.
G
as flows.
Gas does
not flow
.
No
Yes
No
Yes
(LED1 lit?
)
Yes
No
Water
cooling
torch
(Flashes.)
A
ir cooling torch
Y
es
(water
colling)
(Flashes.)
No (air cooling)
Summary of Contents for MOTOWELD-T300D
Page 14: ...14 Fix the gas regulator to prevent it from falling Gas regulator Gas regulator stand...
Page 56: ...56 14 Connection Diagrams 14 1 Connection System Diagram...
Page 59: ...59 15 Lists of Service Components...
Page 60: ...60 Fig 15 1 YWE T30D Front Face Fig 15 2 YWE T30D Rear Face...
Page 63: ...63 Fig 15 3 YWE T30A D 0 Right Side Face Fig 15 3 YWE T30D Right Side Fade...
Page 65: ...65 Fig 15 4 YWE T30D Left Side Face...
Page 67: ...67 Fig 15 5 YWE T30D Base Section...
Page 69: ...69 Fig 15 6 YWE T30D Compartment Barrier Section...