40
YASKAWA
SIEP C730600 0NA MECHATROLINK-4 Technical Manual
INV_CTL_EX Response
Byte
Response
Description
44
Monitor data set to SEL_MON_
E3
Monitor Data Set
Monitor data set to SEL_MON_E3 (Lower)
45
Monitor data set to SEL_MON_E3 (Upper)
46
Not used (Set to 0.)
47
Not used (Set to 0.)
48
Monitor data set to SEL_MON_
E4
Monitor Data Set
Monitor data set to SEL_MON_E4 (Lower)
49
Monitor data set to SEL_MON_E4 (Upper)
50
Not used (Set to 0.)
51
Not used (Set to 0.)
52
Monitor data set to SEL_MON_
E5
Monitor Data Set
Monitor data set to SEL_MON_E5 (Lower)
53
Monitor data set to SEL_MON_E5 (Upper)
54
Not used (Set to 0.)
55
Not used (Set to 0.)
56
Monitor data set to SEL_MON_
E6
Monitor Data Set
Monitor data set to SEL_MON_E6 (Lower)
57
Monitor data set to SEL_MON_E6 (Upper)
58
Not used (Set to 0.)
59
Not used (Set to 0.)
60
Monitor data set to SEL_MON_
E7
Monitor Data Set
Monitor data set to SEL_MON_E7 (Lower)
61
Monitor data set to SEL_MON_E7 (Upper)
62
Not used (Set to 0.)
63
Not used (Set to 0.)
■
INVCMD_STAT_EX
Vendor Specific
bit1
bit0
bit7
bit6
bit5
bit4
bit3
bit2
oPE Error
Drive Ready
Speed Agree
Zero Speed
Main Power Supply
ON
Baseblock Released
Reverse Operation
Forward Operation
Vendor Specific
bit9
bit8
bit15
bit14
bit13
bit12
bit11
bit10
During Run
Not used
Zero Servo
Motor Selection
LOCAL/REMOTE
Power Loss
Recovery/
Momentary Power
Loss Recovery
Fault Reset Signal
being Input
Reserved (0)
Vendor Specific
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Not used
bit31
bit30
bit29
bit28
bit27
bit26
bit25
bit24
Reserved (0)
SEL_MON_E7
Status
SEL_MON_E6
Status
SEL_MON_E5
Status
SEL_MON_E4
Status
SEL_MON_E3
Status
SEL_MON_E2
Status
SEL_MON_E1
Status
Table 9.12 INVCMD_STAT_EX Bits
Bit
Name
Description
0
Forward operation
0: Stop
1: Forward operation
1
Reverse operation
0: Stop
1: Reverse operation
2
Baseblock Released
0: Baseblock
1: Baseblock released
3
Main Power Supply ON
0: Main power supply OFF
1: Main power supply ON