SIEP C730600 0NA MECHATROLINK-4 Technical Manual
39
■
INV_CTL_EX Response
INV_CTL_EX Response
Byte
Response
Description
0
INV_CTL_EX (52 (Hex.))
Command code
1
RWDT
Watchdog data
2
CMD_STAT
Refer to page
3
4
INVCMD_STAT_EX
Refer to page
5
6
7
8
INVCMD_IN
Refer to page
9
10
11
12
Output Frequency
Output Frequency (Lower)
13
Output Frequency (Upper)
14
Not used (Set to 0.)
15
Not used (Set to 0.)
16
Output current
Output current (Lower)
17
Output current (Upper)
18
Not used (Set to 0.)
19
Not used (Set to 0.)
20
SEL_REF_E1
The value set in the command.
21
SEL_REF_E2
22
SEL_REF_E3
23
SEL_REF_E4
24
SEL_REF_E5
25
SEL_REF_E6
26
SEL_REF_E7
27
Reserved (0)
Not used (Set to 0.)
28
SEL_MON_E1
The value set in the command.
29
SEL_MON_E2
30
SEL_MON_E3
31
SEL_MON_E4
32
SEL_MON_E5
33
SEL_MON_E6
34
SEL_MON_E7
35
Reserved (0)
Not used (Set to 0.)
36
Monitor data set to SEL_MON_
E1
Monitor Data Set
Monitor data set to SEL_MON_E1 (Lower)
37
Monitor data set to SEL_MON_E1 (Upper)
38
Not used (Set to 0.)
39
Not used (Set to 0.)
40
Monitor data set to SEL_MON_
E2
Monitor Data Set
Monitor data set to SEL_MON_E2 (Lower)
41
Monitor data set to SEL_MON_E2 (Upper)
42
Not used (Set to 0.)
43
Not used (Set to 0.)