SIEP C730600 0NA MECHATROLINK-4 Technical Manual
17
Command
Code
(Hex.)
Operation
Communication Phases
1
2
3
SYNC_SET
0D
Start Synchronous Communication Command
-
○
△
CONNECT
0E
Establish Connection Command
○
△
△
DISCONNECT
0F
Release Connection Command
○
○
○
MEM_RD
1D
Read Memory Command
-
○
○
INV_CTL
50
Inverter Operation Control Command
-
○
○
INV_CTL_EX
52
Extended Inverter Operation Control Command
-
○
○
○: Can be executed, Δ: Ignored,
–
: Cannot be executed (phase error)
Table 7.3 Sub-Command Communication Phases
Command
Code
(Hex.)
Operation
Communication Phases
1
2
3
NOP
00
No Operation Command
-
○
○
PRM_RD
01
Read Parameter Command
-
○
○
PRM_WR
02
Write Parameter Command
-
○
○
ALM_RD
05
Read Alarm or Warning Command
-
○
○
INV_IO
51
Drive I/O Control Command
-
○
○
○: Can be executed,
–
: Cannot be executed (phase error)
◆
Application Layer Specifications
The data format for the application layer conforms to the MECHATROLINK-4 command specifications for
standard inverter profile.
The JOHB-SMP3 option uses the main commands and sub-commands in the following tables.
Table 7.4 Main Commands
Code
(Hex.)
Name
Function
00
NOP
No Operation Command
01
PRM_RD
Read Parameter Command
02
PRM_WR
Write Parameter Command
03
ID_RD
Read ID Number Command
04
CONFIG
RAM Enter and ROM Enter Command
05
ALM_RD
Read Alarm and Warning Command
06
ALM_CLR
Clear Alarm and Warning Command
0D
SYNC_SET
Start Synchronous Communication Command
0E
CONNECT
Connect Command
0F
DISCONNECT
Release Connection Command
1D
MEM_RD
Read Memory Command
50
INV_CTL
Inverter Operation Control Command
52
INV_CTL_EX
Extended Inverter Operation Control Command
Table 7.5 Sub-Commands
Code
(Hex.)
Command
Function
00
NOP
No Operation Command
01
PRM_RD
Read Parameter Command
02
PRM_WR
Write Parameter Command
05
ALM_RD
Read Alarm and Warning Command
51
INV_I/O
Inverter I/O Control Command