YASKAWA
SIEP C730600 0NA MECHATROLINK-4 Technical Manual
21
PRM_RD Response
Byte
Response
Description
0
PRM_RD (01 (Hex.))
Command code
1
RWDT
Watchdog data
2
CMD_STAT
Refer to page
. If the SIZE data is invalid or MEMOBUS/Modbus register number does not exist,
“
9
”
is set for CMD_
ALM.
3
4
NO
The value (Lower) set in the command.
5
The value (Upper) set in the command.
6
SIZE
The SIZE is the same as the register number set in MEMOBUS/Modbus transfers.
7
Reserved (0)
0 is set.
8
PARAMETER
Sets the data read in the byte set in the command. The option stores the data read for PARAMETER from lower byte (LSB)
to upper byte (MSB). 0 is stored when the field is not used.
0 is stored in PARAMETER when command error occurs.
9
10
・
・
63
■
Example: Reading C1-01 (200 (Hex.))
Byte
Command (Hex.)
Response (Hex.)
4
00
00
5
02
02
6
02
02
7
00
00
8
00
Value set to
C1-01
(Lower)
9
00
Value set to
C1-01
(Upper)
◆
PRM_WR: 02 (Hex.) (Write Parameter Command)
The PRM_WR command writes the internal parameter of the drive for SIZE from the MEMOBUS/Modbus
register number above 100 (Hex.) specified by NO. You can use the command in communication phases 2 and 3.
To save the setting value in the drive, use the CONFIG command. Refer to the drive manual for more information
on MEMOBUS/Modbus register numbers.
PRM_WR Command
Byte
Command
Description
0
PRM_WR (02 (Hex.))
Command code
1
WDT
Watchdog data
2
CMD_CTRL
Refer to page
3
4
NO
MEMOBUS/Modbus register number (Lower)
5
MEMOBUS/Modbus register number (Upper)
6
SIZE
Specify the parameter data size in bytes.
2, 4, 6, and 8 are available.
7
Reserved (0)
Not used
8
PARAMETER
Specify the lower byte (LSB) before the upper byte (MSB) in the size set in the SIZE.
9
10
・
・
63