36
YASKAWA
SIEP C730600 0NA MECHATROLINK-4 Technical Manual
Bit
Name
Description
12
Motor 2 Selection
0: Motor 1
1: Motor 2
13
Zero Servo
1: Zero servo
24
SEL_MON1 Status
0: Disabled
1: SEL_MON1 enabled
25
SEL_MON2 Status
0: Disabled
1: SEL_MON2 enabled
■
INVCMD_IN
Vendor Specific
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Not used
Vendor Specific
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
Not used
Vendor Specific
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Not used
bit31
bit30
bit29
bit28
Vendor Specific
bit27
bit26
bit25
bit24
Reserved (0)
Not used
◆
INV_CTL_EX: 52 (Hex.) (Extended Inverter Operation Control Command)
The INV_CTL_EX commandsets the drive operation, frequency references. The command also selects the
monitor function to monitor.
Up to 7 command functions (SEL_REF_E1 to SEL_REF_E7) and up to 7 monitor functions (SEL_MON_E1 to
SEL_MON_E7) are available for the Inverter Operation Control Command (INV_CTL: 50H).
You can use the command in communication phases 2 and 3.
INV_CTL_EX Command
Byte
Command
Description
0
INV_CTL_EX (52 (Hex.))
Command code
1
WDT
Watchdog data
2
CMD_CTRL
Refer to page
3
4
INVCMD_CTRL_EX
Refer to page
5
6
7
8
INVCMD_OUT
Refer to page
9
10
11
12
Speed reference
Speed Reference (Lower)
13
Speed Reference (Upper)
14
Not used (Set to 0.)
15
Not used (Set to 0.)