6.3 MEMOBUS/Modbus Communications
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
281
Table 6.7 Message Example When Reading the Contents of Non-Consecutive Holding Registers
Byte
Command Message
Response Message (when normal)
Response Message (when there is a fault)
Setting Data
(Hex.)
Setting Data
(Hex.)
Setting Data
(Hex.)
0
Slave address
01
Slave address
01
Slave address
01
1
Function Code
67
Function Code
67
Function Code
E7
2
Subfunction
Code
Upper
01
Subfunction
Code
Upper
01
Error Codes
02
3
Lower
0D
Lower
0D
CRC-16
Upper
EA
4
Data Qty
Upper
00
Byte No.
Upper
00
Lower
31
5
Lower
02
Lower
04
-
6
Holding register
1 No.
Upper
00
Holding register
1 data
Upper
17
-
7
Lower
24
Lower
70
-
8
Holding register
2 No.
Upper
00
Holding register
2 data
Upper
03
-
9
Lower
28
Lower
E8
-
10
CRC-16
Upper
8B
CRC-16
Upper
47
-
11
Lower
29
Lower
ED
-
Note:
The number of bytes set within the response message sets twice the number of data contained in the command message.
■
Writing to Non-Consecutive Holding Registers
The drive uses function code 67 (Hex.) and subfunction code 010E (Hex.) to read data with a maximum of 60 holding
registers.
You must give the holding register number from which to write separately.
shows example messages when you write the frequency reference and torque limit from the drive for slave
1.
uses these specified holding registers data for the examples.
•
0002H: Frequency Reference = 60.00 Hz (6000 = 1770H)
•
0004H: Torque Limit = 150.0% (1500 = 05DCH)
When you rewrite the parameter value with the write command through the
H5-11 [Comm ENTER Command Mode]
setting, you must use the Enter command to save and enable the contents of the changes. Refer to
ENTER Command Mode on page 889
and
for more information.
Table 6.8 Message Example When Writing to Non-Consecutive Holding Registers
Byte
Command Message
Response Message (when normal)
Response Message (when there is a fault)
Setting Data
(Hex.)
Setting Data
(Hex.)
Setting Data
(Hex.)
0
Slave address
01
Slave address
01
Slave address
01
1
Function Code
67
Function Code
67
Function Code
E7
2
Subfunction
Code
Upper
01
Subfunction
Code
Upper
01
Error Codes
02
3
Lower
0E
Lower
0E
CRC-16
Upper
EA
4
Data Qty
Upper
00
Data Qty
Upper
00
Lower
31
5
Lower
02
Lower
02
-
6
Byte No.
Upper
00
CRC-16
Upper
D5
-
7
Lower
04
Lower
FC
-
8
Holding register
1 No.
Upper
00
-
-
9
Lower
02
-
-
Summary of Contents for GA80U4720ABM
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...