5.9 Braking Resistor Installation
410
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Figure 5.85 Reattach the Wiring Cover
9.
Put the terminal cover back in its initial position.
◆
Connect Braking Units in Parallel
To connect two or more braking units in parallel, refer to
for wiring and connector selections.
Braking units have connectors to select master or slave. On the first braking unit, select the master side. On the
second unit and all subsequent units, select the slave side.
Figure 5.86 Connect Braking Units in Parallel
◆
Dynamic Braking Option Overload Protection
To prevent overheating the dynamic braking option, set a sequence to de-energize the drive at the trip contacts of the
thermal overload relay.
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...