F7-23 to F7-32: Dynamic Out Param 1 to 10 for CommCard
No.
(Hex.)
Name
Description
Default
(Range)
F7-23 - F7-27
(03FB - 03FF)
F7-28- F7-32
(0370 - 0374)
Dynamic Out Param 1 to 10
for CommCard
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to the
MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the
values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
0
■
F7-33 to F7-42: Dynamic In Param 1 to 10 for CommCard
No.
(Hex.)
Name
Description
Default
(Range)
F7-33 - F7-42
(0375 - 037E)
Dynamic In Param 1 to 10
for CommCard
Sets Input Assembly 166. The drive sends the values from the MEMOBUS/Modbus address registers
stored for each parameter to Input Assembly 166. The drive returns the default register value for the
option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined.
0
■
F7-60: PZD1 Write (Control Word)
No.
(Hex.)
Name
Description
Default
(Range)
F7-60
(0780)
PZD1 Write (Control Word)
Sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO output) functions as the
STW when
F7-60 = 0, 1, or 2
.
0
■
F7-61: PZD2 Write (Frequency Reference)
No.
(Hex.)
Name
Description
Default
(Range)
F7-61
(0781)
PZD2 Write (Frequency
Reference)
Sets the MEMOBUS/Modbus address for PZD2 (PPO output). PZD2 (PPO output) functions as the
HSW when
F7-61 = 0, 1, or 2
.
0
■
F7-62: PZD3 Write
No.
(Hex.)
Name
Description
Default
(Range)
F7-62
(0782)
PZD3 Write
Sets the MEMOBUS/Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will disable the
PZD3 (PPO output) write operation to the MEMOBUS/Modbus register.
0
■
F7-63: PZD4 Write
No.
(Hex.)
Name
Description
Default
(Range)
F7-63
(0783)
PZD4 Write
Sets the MEMOBUS/Modbus address for PZD4 (PPO output). A value of 0, 1, or 2 will disable the
PZD4 (PPO output) write operation to the MEMOBUS/Modbus register.
0
■
F7-64: PZD5 Write
No.
(Hex.)
Name
Description
Default
(Range)
F7-64
(0784)
PZD5 Write
Sets the MEMOBUS/Modbus address for PZD5 (PPO output). A value of 0, 1, or 2 will disable the
PZD5 (PPO output) write operation to the MEMOBUS/Modbus register.
0
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...