YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
787
■
F1-37: Encoder 2 Signal Selection
No.
(Hex.)
Name
Description
Default
(Range)
F1-37
(03BD)
Encoder 2 Signal Selection
Sets the number of channels for the signal to the encoder option card for motor 2.
0
(0, 1)
0 : A Pulse Detection
1 : AB Pulse Detection
■
F1-46: Deviation 2 Detection Method Selection
No.
(Hex.)
Name
Description
Default
(Range)
F1-46
(1B98)
Deviation 2 Detection
Method Selection
Usually it is not necessary to change this setting. Sets the detection method for
dv2 [Z Pulse Noise
Fault Detection]
.
0
(0, 1)
To detect
dv2
while a multi-pole motor (for example 24 or more poles) is running at zero speed, set
F1-46 = 1
[Mechanical Angle Detection Method]
.
0 : Electrical Angle Detection Method
1 : Mechanical Angle Detection Method
■
F1-47: Deviation 2 Detection Selection
No.
(Hex.)
Name
Description
Default
(Range)
F1-47
(1B99)
Deviation 2 Detection
Selection
Usually it is not necessary to change this setting. Sets the sensitivity of detection for
dv2 [Z Pulse
Noise Fault Detection]
. Increase the value to decrease the sensitivity.
15°
(0 - 180°)
These
F1-46 [dv2 Detection Method Selection]
settings change the setting units of
F1-47
:
•
F1-46 = 0:
F1-47
uses electric angles (deg)
•
F1-46 = 1:
F1-47
uses mechanical angles (one motor rotation is equivalent to a mechanical angle of 360 degrees)
■
F1-50: PG-F3 Option Encoder Type
No.
(Hex.)
Name
Description
Default
(Range)
F1-50
(03D2)
PG-F3 Option Encoder Type
Sets the type of encoder connected to the PG-F3 option.
0
(0 - 2)
0 : EnDat Sin/Cos
1 : EnDat Serial Only
2 : HIPERFACE
■
F1-51: PG-F3 PGoH Detection Level
No.
(Hex.)
Name
Description
Default
(Range)
F1-51
(03D3)
PG-F3 PGoH Detection
Level
The drive will detect
PGoH [Encoder (PG) Hardware Fault]
if the value of this parameter is smaller
than the value of
.
80%
(1 - 100%)
The drive will detect
PGoH
if the value of this parameter is smaller than the value of
.
Regarding the expression
, Sin θ is the single-track (phase B) output from the encoder and Cos θ is
the single-track (phase A) output from the encoder.
Note:
This function is enabled when
F1-20 = 1 [Encoder 1 PCB Disconnect Detect = Enabled]
.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...