550
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
L3-39
(11D3)
Current Limit Filter Time
@Accel
Sets the time constant to adjust the acceleration rate when
L3-01 = 3 [Stall Prevention
during Accel = Current Limit Method]
. Usually it is not necessary to change this setting.
100.0 ms
(1.0 - 1000.0 ms)
L3-40
(11D4)
Current Limit S-Curve @
Acc/Dec
Sets the function to enable and disable the best S-curve characteristic used for current-
limited acceleration.
0 : Disabled
1 : Enabled
0
(0, 1)
◆
L4: Speed Detection
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
L4-01
(0499)
Speed Agree Detection
Level
Sets the level to detect speed agree or motor speed.
Sets the level to detect speed agree or motor speed when
H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2]
.
Determined by A1-02
(Determined by A1-02)
L4-02
(049A)
Speed Agree Detection
Width
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when
H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2]
.
Determined by A1-02
(Determined by A1-02)
L4-03
(049B)
Speed Agree Detection
Level (+/-)
Sets the level to detect speed agree or motor speed.
Sets the speed agree detection level or motor speed detection level when
H2-01 to H2-03 =
13, 14, 15, 16 [MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2,
Frequency Detection 3, Frequency Detection 4]
.
Determined by A1-02
(Determined by A1-02)
L4-04
(049C)
Speed Agree Detection
Width (+/-)
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when
H2-01 to H2-03 = 13, 14, 15, 16
[MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2, Frequency
Detection 3, Frequency Detection 4]
.
Determined by A1-02
(Determined by A1-02)
L4-05
(049D)
Fref Loss Detection
Selection
Sets the operation when the drive detects a loss of frequency reference.
0 : Stop
1 : Run at (L4-06 x Last Reference)
0
(0, 1)
L4-06
(04C2)
Frequency Reference
@Loss of Ref
Sets the frequency reference as a percentage to continue drive operation after it detects a
frequency reference loss. The value is a percentage of the frequency reference before the
drive detected the loss.
80.0%
(0.0 - 100.0%)
L4-07
(0470)
Speed Agree Detection
Selection
Sets the condition that activates speed detection.
0 : No Detection during Baseblock
1 : Detection Always Enabled
0
(0, 1)
◆
L5: Fault Restart
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
L5-01
(049E)
Number of Auto-Restart
Attempts
Sets the number of times that the drive will try to restart.
0
(0 - 10 times)
L5-02
(049F)
Fault Contact at Restart
Select
Sets the function that sends signals to the MFDO terminal set for
Fault [H2-xx = E]
while
the drive is automatically restarting.
0 : Active Only when Not Restarting
1 : Always Active
0
(0, 1)
L5-03
(04A0)
Continuous Method Max
Restart T
Sets the time for which the drive will try to restart. If the drive cannot restart inthe time set
in
L5-03
, the drive detects a fault. This is available when
L5-05 = 0 [Auto-Restart Method
= Continuous/Immediate Attempts]
.
10.0 s
(0.5 - 180.0 s)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...