YASKAWA
TM.iQp.02 iQpump Drive Programming Manual
207
Table 36 480 VAC Drives
Drive Model
CIMR-P7U-
-107
Nominal
Hp
Factory
Default
for
b8-04
Factory
Default
for
C6-02
<0032>
Factory
Default
for
E2-01
Factory
Default
for
E2-03
Factory
Default
for
E2-05
Factory
Default
for
L2-02
Factory
Default
for
L2-03
Factory
Default
for
L2-04
Factory
Default
for
L8-02
Factory
Default
for
L8-06
40P4
0.5/0.75
576.40
15 kHz
1.0
0.6
38.198
0.1
0.1
0.3
95×C
5
40P7
1
447.40
15 kHz
1.6
0.8
22.459
0.1
0.2
0.3
95×C
7.5
41P5
1.5/2
338.80
15 kHz
3.1
1.4
10.100
0.2
0.3
0.3
95×C
10
42P2
3
313.60
15 kHz
4.2
1.5
6.495
0.3
0.4
0.3
90 ×C
10
43P7
5
245.80
15 kHz
7.0
2.3
3.333
0.5
0.5
0.3
95×C
12
45P5
7.5
189.50
15 kHz
13.3
2.6
1.595
1.0
0.6
0.3
95×C
10
47P5
10
145.38
15 kHz
19.9
4.0
1.152
1.0
0.7
0.3
90×C
20
49P0
15
145.46
15 kHz
21.0
4.4
0.922
1.0
0.8
0.3
95°C
23
4011
15/20
140.88
8 kHz
26.5
5.6
0.922
2.0
0.8
0.3
95×C
23
4015
25
126.26
10 kHz
32.9
7.6
0.550
2.0
0.9
0.3
95×C
17
4018
30
115.74
10 kHz
52.3
7.8
0.403
2.0
1.0
0.6
98×C
17
4024
40
89.08
10 kHz
52.0
8.6
0.269
2.0
1.1
0.6
85°C
20
4030
40/50
92.54
8 kHz
65.6
10.9
0.269
2.0
1.1
0.6
85×C
20
4037
60
76.32
8 kHz
79.7
19.1
0.155
2.0
1.1
0.6
85×C
20
4045
75
71.56
8 kHz
95.0
22.0
0.122
2.0
1.2
0.6
90×C
20
4055
100
67.20
5 kHz
130.0
24.0
0.088
2.0
1.2
1.0
90×C
20
4075
125
46.20
5 kHz
130.0
36.0
0.092
2.0
1.3
1.0
98×C
16
4090
150
38.91
8 kHz
156.0
40.0
0.056
2.0
1.5
1.0
108×C
16
4110
200
36.23
5 kHz
190.0
49.0
0.046
2.0
1.7
1.0
100×C
16
4160
250
30.13
5 kHz
270.0
70.0
0.029
2.0
1.8
1.0
108×C
14
4185
300/350
30.57
2 kHz
310.0
81.0
0.025
2.0
0.7
1.0
95×C
15
4220
400/450
27.13
2 kHz
370.0
96.0
0.020
2.0
0.8
1.0
100×C
15
4300
500+
21.76
2 kHz
500.0
130.0
0.014
2.1
0.9
1.0
95×C
15
Note:
b8-04 = Energy Savings Coefficient
C6-02 = Carrier Frequency
E2-01 = Motor Rated Current
E2-03 = Motor No-Load Current
E2-05 = Motor Line-to-Line Resistance
L2-02 = Momentary Power Loss Ride-Thru Time
L2-03 = Momentary Power Loss Minimum Base Block Time
L2-04 = Momentary Power Loss Voltage Recovery Ramp Time
L8-02 = Overheat Pre-Alarm Level
L8-06 = Input Phase Loss Detection Level
Summary of Contents for CIMR-P7U-2011-107
Page 1: ...iQpump Drive Programming Manual Document Number TM iQp 02 ...
Page 204: ...204 YASKAWA TM iQp 02 iQpump Drive Programming Manual THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 208: ...208 YASKAWA TM iQp 02 iQpump Drive Programming Manual THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 209: ...YASKAWA TM iQp 02 iQpump Drive Programming Manual 209 THIS PAGE INTENTIONALLY LEFT BLANK ...