![YASKAWA A1000 HHP Programming Manual Download Page 72](http://html1.mh-extra.com/html/yaskawa/a1000-hhp/a1000-hhp_programming-manual_3232370072.webp)
No.
Parameter Name
Setting Range
Default
d5-05
Speed Limit Bias
0 to 120%
10%
n
d5-06: Speed/Torque Control Switchover Time
Sets the delay time for switching between Speed Control and Torque Control.
No.
Parameter Name
Setting Range
Default
d5-06
Speed/Torque Control Switchover Time
0 to 1000 ms
0 ms
n
d5-08: Unidirectional Speed Limit Bias
Selects how the speed limit bias is applied.
No.
Parameter Name
Setting Range
Default
d5-08
Unidirectional Speed Limit Bias
0, 1
1
Setting 0: Disabled
The speed limit bias is applied in the speed limit direction and the opposite direction.
Setting 1: Enabled
The speed limit bias is applied in the opposite direction of the speed limit only.
u
d6: Field Weakening and Field Forcing
Field Weakening
The Field Weakening function reduces the output voltage to a predefined level to reduce the energy consumption of the motor.
To activate the Field Weakening function, use a digital input programmed for H1-
oo
= 63. Only use Field Weakening with
a known and unchanging light load condition. Use the Energy Saving function (b8-
oo
parameters) when Energy Saving for
various different load conditions is required.
Field Forcing
The Field Forcing function compensates the delaying influence of the motor time constant when changing the excitation current
reference and improves motor responsiveness. Field Forcing is ineffective during DC Injection Braking.
n
d6-01: Field Weakening Level
Sets the level to which the output voltage is reduced when Field Weakening is activated. Set as percentage of the maximum
output voltage.
No.
Parameter Name
Setting Range
Default
d6-01
Field Weakening Level
0 to 100%
80%
n
d6-02: Field Weakening Frequency Limit
Sets the lower limit (in Hz) of the frequency range where field weakening control is valid. The field weakening command is
valid only at frequencies above this setting and only when output frequency is in agreement with the current output frequency
(speed agree).
No.
Parameter Name
Setting Range
Default
d6-02
Field Weakening Frequency Limit
0 to 150.0 Hz
0.0 Hz
n
d6-03: Field Forcing Selection
Enables or disables the Field Forcing function.
No.
Parameter Name
Setting Range
Default
d6-03
Field Forcing Selection
0, 1
0
Setting 0: Disabled
Setting 1: Enabled