H2 Multi-Function Digital Output Settings
H2-
oo
Setting
Function
Description
Page
16
Frequency detection 4
All Modes
Closed: When the output frequency is greater than or equal to the value in L4-03 ±L4-04.
17
Torque detection 1 (N.C.)
All Modes
Open: Overtorque or undertorque has been detected.
18
Torque detection 2 (N.O.)
All Modes
Closed: Overtorque or undertorque has been detected.
19
Torque detection 2 (N.C.)
All Modes
Open: Overtorque or undertorque has been detected.
1A
During reverse
All Modes
Closed: Drive is running in the reverse direction.
1B
During baseblock (N.C.)
All Modes
Open: Drive has entered the baseblock state (no output voltage).
1C
Motor 2 selection
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
OLV
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
OLV
CLV
Closed: Motor 2 is selected by a digital input (H1-
oo
= 16)
1D
During regeneration
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Closed: Motor is regenerating energy into the drive.
1E
Restart enabled
All Modes
Closed: An automatic restart is performed
1F
Motor overload alarm (oL1)
All Modes
Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.
20
Drive overheat pre-alarm (oH)
All Modes
Closed: Heatsink temperature exceeds the parameter L8-02 value.
22
Mechanical weakening
detection
All Modes
Closed: Mechanical weakening detected.
2F
Maintenance period
All Modes
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require
maintenance.
30
During torque limit
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLV
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
OLV
CLV/PM
CLV
Closed: When the torque limit has been reached.
31
During speed limit
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Closed: Speed limit has been reached.
32
During speed limit in Torque
Control
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Closed: Speed limit has been reached while using Torque Control.
33
Zero Servo complete
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
Closed: Zero Servo operation has finished.
37
During frequency output
All Modes
Open: Either the drive has stopped or baseblock, DC Injection Braking, or Initial Excitation is
being performed.
Closed: Drive is running the motor (not in a baseblock state and DC Injection is not being
performed).
38
Drive enabled
All Modes
Closed: Multi-function input set for “Drive enable” is closed (H1-
oo
= 6A)
39
Watt hour pulse output
All Modes
Output units are determined by H2-06. Outputs a pulse every 200 ms to indicate the kWh count.