B95W
Maintenance
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
139 / 306
6
20
Cleaning the cooling fins
Clean the combination cooler by blowing it out with compressed air from the
air discharge side.
If necessary, e. g. in if the cooler is contaminated with oil, clean it with cold
cleansing agent or steam cleaning equipment.
J
For this work, park the machine on a washing area equipped with an oil
separator.
After cleaning, run the engine until it reaches the operating temperature so
that it can dry the water cooler.
Reversing fan
(option)
Use the reversing fan of the engine to remove any foliage or the like from the
cooler.
J
See chapter “Submenu, fan control”.
CAUTION
Risk of machine damage
If the machine is cleaned while hot or while the engine is
running, there is a risk of damage. Exposure to high
pressure during cleaning can damage the cooler.
Z
Only perform cleaning after stopping the engine and letting
it cool down.
Z
Maintain an adequate distance during cleaning.
CAUTION
Risk posed by overheating
A dirty cooler can cause the engine/hydraulic system to
overheat and result in serious damage to the machine.
Z
Clean the cooler carefully.
WARNING
Danger posed by dislodged parts
Air cleaning with compressed air can dislodge parts and
result in eye injuries.
Z
Wear personal protective equipment.
WARNING
Risk posed by hot / moving machine parts
Machine parts may move while the machine is running.
Fluids/machine parts may remain hot even after the
machine has been parked. Danger of crushing and burns.
Z
Only perform cleaning after stopping the engine and letting
it cool down.
Summary of Contents for B95W
Page 2: ......
Page 8: ...B95W Table of contents 6 306 1 01_Inhaltsverzeichnis_enIVZ fm V1 0 1 8 17 10 ...
Page 52: ...B95W Description 50 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 58: ...B95W Description 56 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 206: ...B95W Maintenance 204 306 6 06_Wartung und Pflege_en fm V1 0 1 8 17 20 ...
Page 208: ...B95W Operation 206 306 7 07_Bedienung_en fm V1 0 1 8 17 26 ...
Page 272: ...B95W Transport 270 306 8 08_Transport_en fm V1 0 1 8 17 27 ...
Page 302: ...B95W Troubleshooting 300 306 10 10_Fehlerbeseitigung_en fm V1 0 1 8 17 30 ...
Page 309: ......