B95W
Troubleshooting
10_Fehlerbeseitigung_en.fm - V1.0 - 1.8.17
299 / 306
10
30
10.3.2 Immobilizer faults
Fault
Immobilizer not working
Cause
•
Plug-in contacts not connected to power supply
•
Antenna cable not plugged in or defective
•
Key contains a transponder that has not been taught in
Corrective
measure
Inspect power supply at plug-in contacts
Check antenna plug-in connection
Check antenna cable
Use key with matching transponder
Fault
Not possible to set up new keys
Cause
•
Terminal 30 not connected to control unit
•
No or incorrect master key used previously (red grip)
•
Time for master key in ignition too short or too long
•
Key for setup does not have transponder
•
Defective antenna
•
Setup time for key in ignition too short
Corrective
measure
Connect terminal 30 to control unit
Use master key
Calculate time for master key correctly
Check whether the key being taught in has a transponder
Check whether the antenna is working
Extend the teach-in time for the key in the ignition lock
Fault
Not possible to clear taught-in keys
Cause
•
No or incorrect master key used (red grip)
•
Time for master key in ignition lock too short
•
Defective antenna
Corrective
measure
Use the correct master key
Calculate time for master key correctly
Check whether the antenna is working
Summary of Contents for B95W
Page 2: ......
Page 8: ...B95W Table of contents 6 306 1 01_Inhaltsverzeichnis_enIVZ fm V1 0 1 8 17 10 ...
Page 52: ...B95W Description 50 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 58: ...B95W Description 56 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 206: ...B95W Maintenance 204 306 6 06_Wartung und Pflege_en fm V1 0 1 8 17 20 ...
Page 208: ...B95W Operation 206 306 7 07_Bedienung_en fm V1 0 1 8 17 26 ...
Page 272: ...B95W Transport 270 306 8 08_Transport_en fm V1 0 1 8 17 27 ...
Page 302: ...B95W Troubleshooting 300 306 10 10_Fehlerbeseitigung_en fm V1 0 1 8 17 30 ...
Page 309: ......