20
Changing the main cartridge
Fig. 6-11 Changing the main cartridge
1
Filter housing
2
Safety cartridge
3
Nut
4
Air filter cartridge
5
Cover
6
Dust ejection valve
7
Retaining bracket
Open the retaining brackets (7) and remove the cover (5) with the dust
ejection valve
Slightly turn and pull out the air filter cartridge (4) and dispose of it.
Record the maintenance work in the corresponding marked fields on the
safety cartridge (2).
Clean the filter body (1) with a damp cloth, especially the seal area for the air
filter cartridge.
Check the new air filter cartridge for signs of damage.
Turning the new air filter cartridge slightly, insert it into the filter body.
Fit the cover with the dust ejection valve pointing down (pay attention to the
position of the dust ejection valve) and fasten it using the retaining clips.