38
4. Operating procedures
Useful functions (RS485 communication function)
Program operation parameters
Name
Identifier
Command
Setting
Step
№
select
STN
R/W/*/*
00001
~
00099
:
Steps 1
~
99
Motor output
F01
~
F99 R/W/*/*
In motor output operation selection,
When ON/OFF control is selected
00000
:
Motor control disabled
00001
:
Motor control enabled
When level control is selected
00000
:
Motor control disabled
00001
~
00010
:
Levels 1
~
10
Auto Start operation parameter
Name
Identifier
Command
Setting
Auto Start time setting
SST
R/W/*/*
When time control is selected
00000
~
09959
:
0hr 0min
~
99hr 59min
*1
H0100
~
H9999
:
100hrs
~
9999hrs
When time control is selected
00000
~
02359
:
hr 0min
~
23hrs59min
Auto Stop operation parameter
Name
Identifier
Command
Setting
Auto Stop time setting
SPT
R/W/*/*
When time control is selected
00000
~
09959
:
0hr 0min
~
99 hr 59min
*1
H0100
~
H9999
:
100hrs
~
9999hrs
When time control is selected
00000
~
02359
:
0hr 0min
~
23hrs 59min
Other parameters
Name
Identifier
Command
Setting
Dominical year setting
YAR
R/W/*/*
00000
~
00099
:
0
~
99 years
Month setting
MON
R/W/*/*
00001
~
00012
:
1
~
12 month
Day setting
DAY
R/W/*/*
00000
~
00031
:
1
~
31 day
Hour setting
HOU
R/W/*/*
00001
~
00012
:
0
~
23 hour
Minute setting
MIN
R/W/*/*
00001
~
00012
:
0
~
59 minute
Power ON/OFF
POW
R/W/*/*
00000
:
Power OFF
*3
00001
:
Power ON
Run/stop
RUN
R/W/*/*
00000
:
Stop
*3
00001
:
Run
Operation mode selection OKS
R/W/*/*
00000
:
Fixed Temp. operation select
00001
:
Program operation selection