10
Setup Mode Settings and Display Order
•
C
0
1
:
Key lock
•
C
0
2
:
Temperature unit
•
C
0
3
:
Direct/reverse operation
•
C
0
4
:
Input range
•
C
0
5
:
Decimal point position
•
C
0
6
:
PV range lower limit
•
C
0
7
:
PV range upper limit
•
C
0
9
:
Lower SP limit
•
C
1
0
:
Upper SP limit
•
C
1
1
:
Preset output value
•
C
1
2
:
Operation mode display
•
C
1
3
:
Number of SPs used
•
C
1
4
:
Event 1 type
•
C
1
5
:
Event 2 type
•
C
1
6
:
Event operation when
READY
•
C
1
7
:
External switch input 1
type
•
C
1
8
:
External switch input 2
type
•
C
2
1
:
READY key settings
•
C
2
2
:
Communications address
•
C
2
3
:
Communications condi-
tions
•
C
2
4
:
Cold junction compensa-
tion
•
C
2
5
:
Selection of time-propor-
tional control operation
Parameter Mode Settings and Display Order
•
C
T
R
L
:
Control method
•
A
T
:
Auto-tuning
•
S
P
0
:
No. 0 SP value
•
S
P
1
:
No. 1 SP value
•
S
P
2
:
No. 2 SP value
•
S
P
3
:
No. 3 SP value
•
P
:
Proportional band
•
I
:
Reset time
•
D
:
Rate time
•
O
L
:
Output limit low
•
O
H
:
Output limit high
•
R
E
:
Manual reset value
•
S
B
:
Self-tuning startup width
•
D
I
F
F
:
Differential gap
•
C
Y
C
L
:
Time-proportional cycle
•
P
B
I
A
:
PV bias value
•
H
Y
S
I
:
Event 1 hysteresis
•
D
L
Y
I
:
Event 1 ON delay time
•
H
Y
S
2
:
Event 2 hysteresis
•
D
L
Y
2
:
Event 2 ON delay time
•
F
I
L
T
:
PV filter
Operation Mode Display Order
•
:
Basic display state
•
S
P
-
0
:
No. 0 SP value
•
S
P
-
1
:
No. 1 SP value
•
S
P
-
2
:
No. 2 SP value
•
S
P
-
3
:
No. 3 SP value
•
O
v
T
:
Manipulated variable
•
C
T
:
Current value (CT)
•
T
1
:
Remaining timer 1 time
•
T
2
:
Remaining timer 2 time
•
e
1
L
O
:
Event 1
(
E
1
)
Lower limit
•
E
1
H
I
:
Event 1
Upper limit
•
E
2
L
O
:
Event 2
(
E
2
)
Lower limit
•
E
2
H
I
:
Event 2
Upper limit
5-1
Overall Operation Flow
The controller enters the Operation mode when power is
turned ON.
Hold down the
PARA
key for three seconds to change modes,
and use this key to move setup items between modes.
Items that are shaded are not displayed de-
pending on the setup or installed options.
Chapter 5 INITIAL SETTINGS
RDY
PV
SP
2
0
0
0
RDY
PV
SP
e
1
l
O
0
e
2
h
1
RDY
PV
SP
PARA
PARA
PARA
RDY
PV
SP
C
T
R
L
RDY
PV
SP
1
0
S
d
C
C
Y
C
L
d
L
Y
1
S
P
1
0
5
RDY
PV
SP
0
RDY
PV
SP
PARA
PARA
PARA
RDY
PV
SP
0
PARA
0
RDY
PV
SP
0
RDY
PV
SP
PARA
PARA
PARA
RDY
PV
SP
0
C
0
1
C
0
2
C
2
1
Power ON
This value is displayed
for 6 seconds.
No key operation for
1 minute or more.
No key operation for
1 minute or more.
PARA
Hold down the
key for
3 seconds.
PARA
Hold down the
key for
3 seconds.
PARA
Hold down the
key for
1 second.
Operation mode
Setup mode
Parameter mode
PV/SP value normal display mode
key
key
key
key
key
key
key
key
key
key