3-6-4 When emergency stop is input
READY
END
BUSY
EMG
Emergency stop
5ms or less
1ms or less
Dedicated
command
■
The READY signal turns off. The BUSY signal also turns off while a dedicated command is
being executed. The END signal remains unchanged.
■
To enable robot operation, cancel emergency stop to turn on the READY signal, then input the
servo recovery command (SERVO).
3-6-5 When alarm is issued
READY
END
BUSY
Alarm
Dedicated
command
5ms or less
1ms or less
■
The READY, BUSY and END signals all turn off.
■
Correct the problem while referring to "13-2 Alarm and Countermeasures".