11-
13
11
11-5 Communication Command Description
COMMUNICA
TION WITH PC
(15)@P <point number>
Sets the point variable P.
Point number
: This can be any value from 0 to 999.
Transmission example
: @P 100 c/r l/f ............................... Set the point variable P to 100.
Response example
: OK c/r l/f
c
CAUTION
The contents of the point variable P are held even when the SRCP30 controller is turned off. However, when the
program is reset or when the program reset is applied for example by switching the execution program, the point
variable P will be initialized to 0.
(16)@P+
Adds 1 to the point variable P.
Transmission example
: @P+ c/r l/f .................................... Increments the point variable P.
(P
←
P+1)
Response example
: OK c/r l/f
(17)@P-
Subtracts 1 from the point variable P.
Transmission example
: @P- c/r l/f ..................................... Decrements the point variable P.
(P
←
P-1)
Response example
: OK c/r l/f
Summary of Contents for SRCP30
Page 1: ...User s Manual ENGLISH E E104 Ver 1 02 SRCP30 YAMAHA SINGLE AXIS ROBOT CONTROLLER MF100 ...
Page 2: ......
Page 8: ...vi MEMO ...
Page 26: ...2 10 MEMO ...
Page 130: ...8 34 MEMO ...
Page 144: ...9 14 MEMO ...
Page 174: ...10 30 MEMO ...
Page 216: ...12 10 MEMO ...
Page 232: ...14 4 MEMO ...
Page 233: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Page 238: ...MEMO 15 6 ...