For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
33/273
Removal of the pick-up automatic height check jig (JG-0342)
(1) Remove the automatic height check jig (JG-0342).
Remove the jig using the reverse procedure for the "Pick-up Level offset" in Item
1.4.5.5 in Chapter 1.
NOTICE
Do not leave any jig or tool inside the machine.
1.4.5.6. PEC Recognition Camera & Beam Offset
Under each of the following conditions, this teaching operation is required.
It would affect the placement accuracy directly.
The in-house adjustment is to be performed.
The machine is to be delivered.
The head has been changed.
The PEC recognition camera is to be changed.
The X- axis or Y-axis linear scale and scale head are to be changed.
Purposes
This data corrects the deviation from the designed distance from the machine reference
coordinate origin or head origin position to the PEC recognition camera center.
Teaching Operation Procedure (At time of Delivery)
(1) Press the [Maint.] button in the operation window and press the [Ship. Adj.] button.
Then, select either [All] button, or [1] or [2] button in the "Select Beam" selection
box in the "PCB Recog/Beam" window.
(2) Select [Not use] in the "Glass Jig" selection box.
* When there is a glass jig, select [Use] button.
(3) Press the [Teach Start] button and [START] button.
(4) Make a note of the values in "Before" and "After" sections.
(5) Press the [Save] button to save the data.
Fig.A29