For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
30/273
(3) Clamp the PLATE using the following method.
Open the "Setup" window and then, "MNL XFER" window. Execute the PCB
positioning in the "MNL XFER" window.
Fig. A24
Note:
Move up the Z-clamp in CNVR-R as the same as in CNVR-L.
In the PCB positioning operation performed in this window, the PCB stopper is not activated.
NOTICE
Take the greatest care so that the PC board does not touch and
scratch the light projector or the side view camera.
Teach Start
(1) Return to the Placement Height Teaching window and after the head is selected,
Select "Teach Start (Shipment)" and press the [START] button.
(2) Attach the master nozzle onto the No. 1 nozzle position in the other head and
preform the chute level teaching after the NL and master nozzle teaching operations.
(3) Save the data.
1.4.5.3. Chute Level (Perform the teaching selecting "Teach Start (Shipment)")
Fig. A25