For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
23/273
1.4.4. Offset in the Installation Operation (High-Speed Head)
1.4.4.1. Differences from SIGMA-G5S and Precautions (Installation Adjustment Related)
(1) Leveling/Running-In/Data Save
(1.1) The bank feeder change cart specialized for SIGMA-G5S is used.
(1.2) For NT-100 for the communication with the machines, the version
recommended by the Quality Assurance Department, is to be used. For the use
of NT-100, the license for SIGMA-G5SII is required.
(2) Offset Measurement/Teaching
(2.1) The origin position of the DD motor is the same as that in SIGMA-G5S.
(The position of the No. 1 nozzle is inside the machine when the DD motor is
at the home position.)
(2.2) Insert the nozzle or jig carefully so that such nozzle or jig is not interfered with
the side view camera, etc.,
(2.3) The zeroing operation is performed in the adjustment operation using the
control menu.
(2.4) The X-axis has been changed from linear driving type to ball screw driving
type. Therefore, when the X-axis is moved manually, it feels slightly heavier.
When the X/Y-axis is moved in the Manual Operation window (displayed from
Control Window), it can be moved quickly and efficient operation is available.
(2.5) The standard value of the master nozzle offset is 0.2 to 0.7 mm.
(3) Placement Accuracy Adjustment
(3.1) For the high-speed nozzle, use the nozzles for SIGMA series.
(0402/HG24C, 0603/HG33C, 1005/HG52C)
(3.2) For BARON accuracy measurement program, the SIGMA-G5SII dedicated
data is required. (There are data items each for L/R flow and Reference.)
(3.3) The tape feeder for SIGMA-G5S is used and the components are set on it.
Model
Tape Width
×
Feed Pitch
(mm)
Types
of Tape
Standard Set Reel
Outer Diameter
×
Width (mm)
Chute
Height
(mm)
Referential
Components
Remarks
GT-38080
GD-
38080
8 × 2
Paper
178 to 382
×
14.4
100.4
1005
Barcode Label
Color : White
8 × 4
2012
3216
3225
8 × 2
Embossed
8 × 4
GD-
38083
8 × 1
Paper
0402
0603
1005
Barcode Label
Color : Blue +
White
Applicable to 1
mm pitch tape
8 × 2
8 × 2
Embossed
Fig. A19
(3.4)
The USL/LSL and standards used in the CPK measurement, are as follows.
0603 X,Y Total ±0.025 Theta: 5 degrees, CPK Value: 1.00 or more
For Each Angle ±0.030
CPK Value: 1.00 or more