MOTIF XS6/MOTIF XS7/MOTIF XS8
118
[Check item]
Check that the value at the right side of the display increases
from +0 to +8 smoothly when the encoder is turned clockwise,
and decreases from +0 to –8 smoothly when the encoder is
turned counterclockwise, and that judgment is OK.
[Judgment indication]
OK
04 : Encoder
TEST
MOTIF XS Test Program
yy: Target value
xx: Current value
Encoder
< yy >
xx
04 : Encoder
TEST
MOTIF XS Test Program
Encoder
OK
NG: No indication
[MIDI code output for judgment result]
OK: A0 05 02
NG: No output
[How to quit test]
When the judgment is shown and output, the test will be
completed and item selection condition will be selected.
If the judgment is NG on the way, refer to “
D. How to carry
out tests when judged as NG
test program.
[Others]
None
[First indication]
Press [ENTER]
05 : Knob
TEST
MOTIF XS Test Program
Knob1
Knob3
Knob5
Knob7
Knob2
Knob4
Knob6
Knob8
05 : Knob
TEST
MOTIF XS Test Program
yyy: Target value
xxx: Current value
Knob 1
< yyy > xxx
Knob 2
< yyy > xxx
Knob 3
< yyy > xxx
Knob 4
< yyy > xxx
Knob 5
< yyy > xxx
Knob 6
< yyy > xxx
Knob 7
< yyy > xxx
Knob 8
< yyy > xxx
T05: Knob
(Test
Code:
A00600)
[Test contents]
Check that knobs 1 to 8 work normally.
Compare the AD data from the EBUS controller with the
target value on the LCD.
[Test method]
Turn each Knob according to an LCD indication as follows
smoothly:
Knob 1 to 8: 0 [min.] (0 to 1)
"
127 [max.] (126 to 127)
"
64
[center] (62 to 66).
The order of the knobs to be checked is not designated.