4-12
Outboard motor troubleshooting
S
ymptom 1: Y-COP lock and unlock function, but there is no answer-back (beep).
Troubleshooting the PTT unit
S
ymptom 1: PTT unit does not operate.
Symptom 2
Cause
Checking steps
See
page
—
Buzzer malfunction
Check the buzzer.
—
Short, open, or loose con-
nection of the wire harness
Measure the buzzer input voltage.
—
Check the Y-COP circuit.
—
Symptom 2
Cause
Checking steps
See
page
PTT relay does not
operate
Blown fuse
Check the fuse.
PTT switch malfunction
Check the PTT switch.
PTT relay malfunction
Check the PTT relay.
Short, open, or loose con-
nection of the wire harness
Measure the PTT switch input volt-
age.
Measure the PTT relay input volt-
age.
Check for continuity between the
PTT switch and the PTT relay.
PTT motor does not
operate
PTT motor malfunction
Check the PTT motor.
Bent trim and tilt ram
Check the trim and tilt ram.
Stuck trim and tilt ram
Disassemble and check the PTT
unit.
Short, open, or loose con-
nection in PTT motor circuit
Check for continuity between the
PTT motor and the PTT relay termi-
nal.
PTT fluid pressure
does not increase
Manual valve open
Check the manual valve.
Insufficient PTT fluid
Add sufficient PTT fluid.
PTT fluid leakage
Check for PTT fluid leakage.
Clogged fluid passage
Disassemble and check the PTT
unit.
Check the filter for dirt and obstruc-
tions.
Check the valves for damage.
Check the fluid passages for ob-
structions.
PTT motor malfunction
Check the PTT motor.
Gear pump malfunction
Check the gear pump operation.
Summary of Contents for F30B 2018
Page 1: ...6BG 28197 ZX 11 LIT 18616 03 84 USA CAN AUS and NZL Worldwide 6BG 6BT 6BG 6BT ...
Page 22: ...1 Specification Specification data 1 1 External dimensions 1 1 Clamp bracket dimensions 1 9 ...
Page 35: ...2 3 Electronic control system Electrical components 3 4 5 6 7 8 9 10 11 1 2 ...
Page 178: ...7 23 Wire harness 2 3 1 a c b 3 4 5 ...
Page 342: ...Jul 2018 ABE E ...