5-46
PTT system
Checking the PTT switch (tiller handle
model)
1.
Measure:
• PTT switch input voltage
Out of specification
Check the wire har-
ness for continuity.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the PTT switch connectors “a”.
b.
Measure the input voltage between the
PTT switch connector and ground.
c.
Connect the PTT switch connectors.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
2.
Check:
• PTT switch continuity
Out of specification
Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the PTT switch connector.
b.
Check the PTT switch for continuity.
c.
Connect the PTT switch connector.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Checking the trim sensor
1.
Measure:
• Trim sensor resistance
Out of specification
Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the trim sensor coupler “a”,
and then remove the trim sensor.
b.
Measure the trim sensor resistance.
Input voltage
12 V
Red (R)–Ground
R
a
UP
D
N
Lg
S
b
R
b
a
c
b
a
c
Lg
R
S
b
PTT switch continuity
Switch po-
sition
Terminal
“a”
“b”
“c”
UP
Free
DN
Free position resistance
239–379
(F30A, F30BET,
F30HA, F40A, F40FET, F40HA)
Setting resistance
9–11
(F30A, F30BET, F30HA,
F40A, F40FET, F40HA)
a