E
STARTER MOTOR (EH/E MODELS)
ELEC
a
2
1
3
4
5
Brush holder inspection
1. Measure:
9
Brush length
a
Out of specification
→
Replace.
2. Check:
9
Brush unit continuity
Out of specification
→
Replace.
8-26
Brush unit continuity:
Brush
1
- Brush
2
Continuity
Brush
3
- Brush
4
Continuity
Brush
1
,
2
- Bracket
5
No continuity
Brush
3
,
4
- Bracket
5
Continuity
Brush length limit:
6.4 mm (0.25 in)