E
IGNITION SYSTEM
ELEC
10
1, 2
Br
L
O
B
IGNITION SYSTEM PEAK VOLTAGE
w
When checking the CDI unit do not touch
any of the connections of the digital tester
lead wires.
1. Measure:
9
CDI unit output peak voltage
Below specification
→
Replace the
ignition coil or check the CDI unit.
2. Measure:
9
Charge coil output peak voltage
Below specification
→
Replace the
charge coil.
8-13
Output peak voltage
O-B
r/min
Cranking
1,500
3,500
Opened Closed
V
120
115
160
160
Output peak voltage
O-B
r/min
Cranking
1,500
3,500
Opened Closed
V
120
120
160
160
Output peak voltage
Br-L
r/min
Cranking
1,500
3,500
Opened Closed
V
130
135
180
180
6 A model
6 A model
Output peak voltage
Br-L
r/min
Cranking
1,500
3,500
Opened Closed
V
130
135
180
180
10 A model
10 A model