– 13 –
9
Be sure to ground (earth) the
generator.
NOTE:
Use ground (earth) lead of suffi-
cient current capacity.
1
Lead diameter
Ground (earth) Lead
Diameter:
0.12 mm (0.005 in)/ampere
EX:
10 Ampere
→
1.2mm
(0.05 in)
G-385
CONNECTION NOTES
9
Do not connect the generator to
a commercial power outlet.
9
Do not connect the generator in
parallel with any other genera-
tor.
1
Correct
2
Incorrect
w
Before the generator can be con-
nected to a building’s electrical
system, a licensed electrician
must install an isolation (trans-
fer) switch in the building’s main
fuse box. The switch is the con-
nection point for g enerator
power and allows selection of
generator or main line power to
the building. This will prevent the
generator from charging the
main power line (backfeeding)
when the main power supply has
failed or has been turned off for
743-026
q
743-027
q
w
q
w
9
务必接好地线。
注意:
确保地线能承载足够的电流。
1
地线的直径
地线
直径:
0.12mm(0.005in)/A
例:
10A → 1.2mm
(0.05in)
G-385
接线注意事项
9
切勿将本发电机与市电连接。
9
切勿将本发电机与其他发电机并
联使用。
1
正确
2
不正确
在将发电机与建筑物的电力系统
连接之前,经认可的电气师必定会在
建筑物的主保险箱中安装一个断开
(传输)开关。此开关是发电机与电力
系统的连接点,可以选择是使用发电
机还是使用干线电源为建筑物供电。
当干线电源有问题,或为修理供电线
路而切断干线电源时,这可以防止发
电机为干线供电(反馈)。电源反馈会
使维修线路的人员触电死亡或受伤。
q
警告
9C1-9-N2̲001-030
07.1.25, 10:41
Page 13
Adobe PageMaker 6.5J/PPC
Summary of Contents for EDL13000TE
Page 136: ......
Page 137: ......
Page 138: ......