Chapter 6
Component Guide
DME Designer Owner’s Manual
328
5
LPF
Type
Thru
6 dB/Oct
12 dB/Oct AdjustGc
12 dB/Oct Butrwrth
12 dB/Oct Bessel
12 dB/Oct Linkwitz
18 dB/Oct AdjustGc
18 dB/Oct Butrwrth
18 dB/Oct Bessel
24 dB/Oct AdjustGc
24 dB/Oct Butrwrth
24 dB/Oct Bessel
24 dB/Oct Linkwitz
36 dB/Oct AdjustGc
36 dB/Oct Butrwrth
36 dB/Oct Bessel
48 dB/Oct AdjustGc
48 dB/Oct Butrwrth
48 dB/Oct Bessel
48 dB/Oct Linkwitz
Sets the attenuation for each octave and the
filter type.
[THRU] turns off the filter.
6
Frequency
20 Hz to 20 kHz
Sets the LPF cutoff frequency.
7
Gc
-6 dB to 6 dB
When [Adjustable Gc] is selected for [Type],
this sets the gain for the cutoff frequency.
8
HPF
Type
Thru
6 dB/Oct
12 dB/Oct AdjustGc
12 dB/Oct Butrwrth
12 dB/Oct Bessel
12 dB/Oct Linkwitz
18 dB/Oct AdjustGc
18 dB/Oct Butrwrth
18 dB/Oct Bessel
24 dB/Oct AdjustGc
24 dB/Oct Butrwrth
24 dB/Oct Bessel
24 dB/Oct Linkwitz
36 dB/Oct AdjustGc
36 dB/Oct Butrwrth
36 dB/Oct Bessel
48 dB/Oct AdjustGc
48 dB/Oct Butrwrth
48 dB/Oct Bessel
48 dB/Oct Linkwitz
Sets the attenuation for each octave and the
filter type.
[THRU] turns off the filter.
9
Frequency
20 Hz to 20 kHz
Sets the HPF cutoff frequency.
)
Gc
-6 dB to 6 dB
When [Adjustable Gc] is selected for [Type],
this sets the gain for the cutoff frequency.